Based on the above information, shielding effectiveness is determined more by openings rather than the shield materials. The opening around the perimeter of larger components, such as doors, vents, access panels and viewing apertures, present the greatest effect on the shielding and are the most difficult to seal. There are basically two ways to electrically connect the mating surfaces; first, by reducing the slot length through the use of conductive fasteners or welding at close intervals, second, through the use of RF gaskets to seal the opening. For additional information, please contact our Customer Service Department.